Products
Our products can be used indoor and outdoor.
In addition to evacuation guidance signs that comply with ISO 22578, we also manufacture products that meet the
customer's budget and wishes according to the intended use. We also offer comprehensive proposals for the construction
of a phosphorescent evacuation guidance sign system, so please feel free to contact us.
Lineup
Products for outdoor use
Processible materials
Our phosphorescent products are fully compliant with the afterglow luminance specified in ISO 22578 and DIN 67510-4. The classifications corresponding to each standard are as follows.
Products |
ISO 22578 |
JIS Z 9098 |
DIN 67510 |
JIS Z 9107 |
|
---|---|---|---|---|---|
Aluminum Phosphorescent Sign | Ⅱ | Ⅱ | - | - | |
Aluminum Phosphorescent Non-slip | Ⅰ | Ⅰ | E | JD | |
Phosphorescent Road Studs | Ⅱ | Ⅱ | - | - | |
Phosphorescent Sheet | Ultra-high luminance | Ⅰ | Ⅰ | E | JD |
High luminance | Ⅰ | Ⅰ | D | JC | |
Reflective Luminous Sheet | Ⅰ | Ⅰ | E | JC |
- “Processible materials” requires appropriate measures when used in the outdoors.
Please contact us for more information.
Related information
The light emitted when the phosphorescent material emits light is called "phosphorescence".
The luminance of phosphorescence is expressed in mcd/㎡, and each standard defines the following classifications.
ISO 22578 and JIS Z 9098
classification |
Minimum luminance at 720 min decay time mcd/㎡ |
---|---|
Ⅰ | 3 |
Ⅱ | 10 |
Luminance test of the phosphorescent disaster type evacuation guidance sign uses a xenon lamp, irradiates with ultraviolet intensity (measurement wavelength range 360 to 400 nm) 400 μW for 60 minutes, blocks the light, and measures the value 720 minutes later.
JIS Z 9107
classification |
Minimum luminance(mcd/㎡) after a decay time of |
||||
---|---|---|---|---|---|
2 min | 10 min | 20 min | 30 min | 60 min | |
JA | 210 | 50 | 24 | 15 | 7 |
JB | 440 | 105 | 50 | 31 | 15 |
JC | 880 | 210 | 100 | 62 | 30 |
JD | 1,760 | 420 | 200 | 124 | 60 |
Conditions of excitation luminosity: Irradiate fluorescent lamp 200 lux for 20 minutes.
DIN 67510
classification |
Minimum luminance(mcd/㎡) after a decay time of |
|||
---|---|---|---|---|
2 min | 10 min | 30 min | 60 min | |
A | 108 | 23 | 7 | 3 |
B | 210 | 50 | 15 | 7 |
C | 690 | 140 | 45 | 20 |
D | 1,100 | 260 | 85 | 35 |
E | 2,200 | 520 | 170 | 70 |
Conditions of excitation luminosity: Xenon lamp 1,000 lux for 5 minutes.